I-ABB 07KT93 GJR5251300R0101 I-Advant Controller module

Igama Brand: ABB

Inombolo yomthetho: 07KT93 GJR5251300R0101

Intengo yeyunithi:999$

Isimo: Okusha kanye nokwangempela

Isiqinisekiso Sekhwalithi: Unyaka ongu-1

Inkokhelo: T/T kanye ne-Western Union

Isikhathi sokuthumela: izinsuku ezingu-2-3

Ichweba Lomkhumbi: China


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Ulwazi olujwayelekile

Ukukhiqiza I-ABB
Into No 07KT93
Inombolo ye-athikili I-GJR5251300R0101
Uchungechunge I-PLC AC31 Automation
Umsuka eSweden
Ubukhulu 73*233*212(mm)
Isisindo 0.5kg
Inombolo Yentela Yamasiko 85389091
Uhlobo
I-Advant Controller Module

 

Idatha enemininingwane

I-ABB 07KT93 GJR5251300R0101 I-Advant Controller module

I-serial interface COM1 ivumela ukufinyelela kumayunithi ayisisekelo e-AC31/CS31 (07 KR 31, 07 KR 91, 07 KT 92 kuya ku-07 KT 94) kanye nephrosesa yezokuxhumana engu-07 KP 62 ye-ABB Procontic T200.

Wonke umsebenzi osebenzayo nowokuhlola we-PLC ungabizwa nge-ASCII plain text telegrams. Imodi yokusebenza "Imodi esebenzayo" kufanele isethwe kusixhumi esibonakalayo se-serial.

Amayunithi axhumeka:
- Itheminali kwimodi ye-VT100
- Ikhompyutha ene-emulation ye-VT100
- Ikhompyutha enohlelo lokuphatha ama-telegrams ombhalo ocacile wemisebenzi yokusebenza nokuhlola

Imodi yokusebenza yesixhumi esibonakalayo:
I-serial interface COM 1 kufanele isethelwe kumodi yokusebenza "Imodi esebenzayo" ukuze kusetshenziswe imisebenzi esebenzayo neyokuhlola.

RUN/MISA shintsha endaweni: MISA Endaweni yokushintsha YEKA, i-PLC ivamise ukumisa imodi yokusebenza "Imodi esebenzayo" ku-COM 1.

SHINTSHA/YIMA shintsha endaweni: RUN Esimeni sokushintsha GIJIMA, imodi yokusebenza "Imodi esebenzayo" isethwe ku-COM 1 lapho kuhlangatshezwana nemibandela eyodwa kwezimbili ezilandelayo:
- Isistimu engashintshi KW 00,06 = 1
or
– Isistimu engaguquki i-KW 00,06 = 0 kanye ne-Pin 6 ku-COM1 inesignali engu-1 (isiginali engu-1 ku-Pin 6 isethwa kusetshenziswa ikhebula lesistimu 07 SK 90 noma ngokungaxhumi i-Pin 6)

Ukuziphatha kwesistimu ye-PLC
Okulandelayo kuyasebenza:
Ukucutshungulwa kohlelo lwe-PLC kubaluleke kakhulu kunokuxhumana ngezixhumi ezibonakalayo ze-serial.

I-PLC ilawula indlela eyamukelayo ye-serial interface COM1 ngokusebenzisa iziphazamiso. Ngesikhathi somjikelezo wohlelo lwe-PLC olusebenzayo, izinhlamvu ezingenayo ngokulandelana zicupha ukushaya kwenhliziyo, ziphazamise uhlelo lwe-PLC olusebenzayo kuze kube yilapho izinhlamvu ezitholiwe zigcinwa kusigcinalwazi sokwamukela. Ukuze ugweme ukuphazamiseka unomphela kokucutshungulwa kohlelo, i-PLC ilawula ukwamukelwa kwedatha ngomugqa we-RTS ukuze kwenzeke esikhaleni esiphakathi kwemijikelezo emibili ye-PLC.

I-PLC icubungula imisebenzi etholwe nge-COM1 kuphela ezikhaleni phakathi kwemijikelezo yohlelo lwe-PLC. Izinhlamvu nazo zikhishwa nge-COM1 kuphela ezikhaleni phakathi kwemijikelezo yohlelo emibili. Ukwehla kokusetshenziswa kwe-PLC kanye nokukhula kwezikhala phakathi kwemijikelezo yohlelo, kuyanda izinga lokuxhumana elingaba khona nge-COM1.

07KT93

ABB 07KT93 GJR5251300R0101 I-Advant Controller module

Yiziphi ukusetshenziswa kwesilawuli semojuli ye-ABB 07KT93 GJR5251300R0101?
Imojula yesilawuli se-ABB 07KT93 Advant iyingxenye yochungechunge lwe-Advant Controller 400 (AC 400), okuwuhlelo lokulawula kwesikhathi sangempela kanye nohlelo oluzenzakalelayo lwezinqubo zezimboni. Ivame ukusetshenziswa ekuqapheni izinhlelo zokusebenza ekukhiqizeni nasekusebenzeni kukagesi

Kungani imojula ye-07KT93 yehluleka ukuqala?
Inkinga yokuxhumeka kwamandla: Hlola ukuthi ugesi we-24V DC uxhumeke ngokujwayelekile yini nokuthi intambo kagesi yonakele noma ayikhululekile yini. Imojuli ngokwayo ingase ibe nephutha. Zama ukushintsha imojuli entsha ukuze uyihlole.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona