ABB 07KT93 GJR5251300R0101 Mana Mana Mana

Kahua:ABB

'ikamu helu:07KT93 GJR5251300R0101

Kumukuai:999$

Kūlana: Mea hou a kumu

Hōʻoia maikaʻi: 1 Makahiki

Uku: T / T a me Western Union

Ka manawa hoʻouna: 2-3 lā

Wawa moku: Kina


Huahana Huahana

Huahana Huahana

ʻIke nui

Hana ʻia ABB
'ikamu helu 07KT93
Helu ʻatikala GJR5251300R0101
moʻo PLC AC31 Automation
Ke kumu Kuekene
Anana 73*233*212(mm)
Kaumaha 0.5 kg
Helu Dute 85389091
ʻAno
Module Hoʻoponopono Kūikawā

 

ʻikepili kikoʻī

ABB 07KT93 GJR5251300R0101 Mana Mana Mana

Hāʻawi ka serial interface COM1 i ke komo ʻana i nā ʻāpana kumu AC31/CS31 (07 KR 31, 07 KR 91, 07 KT 92 a i 07 KT 94) a me ka mea hana kamaʻilio 07 KP 62 o ka ABB Procontic T200.

Hiki ke kāhea ʻia kēlā me kēia hana hana a me ka hoʻāʻo ʻana o ka PLC ma o nā kelepona kikokikona ASCII. Pono e hoʻonoho ʻia ke ʻano hana "Active mode" ma ka interface serial.

Nā ʻāpana hoʻohui:
- Terminal ma ke ʻano VT100
– Kamepiula me VT100 emulation
- Kamepiula me kahi papahana no ka lawelawe ʻana i nā kelepona kikokikona akaka o ka hana a me nā hana hoʻāʻo

Ke ʻano hana o ke alo:
Pono e hoʻonohonoho ʻia ka interface serial COM 1 i ke ʻano hana "Active mode" e hoʻohana ai i nā hana hana a hoʻāʻo.

Hoʻololi RUN/STOP i ke kūlana: STOP Ma ke kūlana hoʻololi STOP, hoʻonohonoho maʻamau ka PLC i ke ʻano hana "Active mode" ma COM 1.

Hoʻololi RUN/STOP ma ke kūlana: RUN Ma ke kūlana hoʻololi RUN, ua hoʻonohonoho ʻia ke ʻano hana "Active mode" ma COM 1 ke hoʻokō ʻia kekahi o kēia mau kūlana ʻelua:
– Pūnaehana mau KW 00,06 = 1
or
- Pūnaehana mau KW 00,06 = 0 a me Pin 6 ma COM1 he 1-hōʻailona (1-hōʻailona ma Pin 6 ua hoʻonohonoho ʻia ma ka hoʻohana ʻana i ke kelepona ʻōnaehana 07 SK 90 a i ʻole ka hoʻopili ʻana i ka Pin 6)

ʻO ka hana ʻōnaehana o ka PLC
Pili kēia mau mea:
ʻO ka hana ʻana o ka papahana PLC ka mea nui ma mua o ke kamaʻilio ʻana ma o nā kikowaena serial.

Mālama ka PLC i ka loaʻa ʻana o ka ʻaoʻao serial COM1 ma o nā interrupts. I ka holo ʻana o ka polokalamu PLC, ʻo nā huaʻōlelo e hiki mai ana e hoʻoulu i ka pulse interrupt, e keakea ana i ka polokalamu PLC e holo nei a hiki i ka mālama ʻia ʻana o nā huaʻōlelo i loaʻa i ka buffer loaʻa. I mea e pale ʻole ai i ka hoʻopau mau ʻana o ka hoʻoili ʻana o ka papahana, mālama ka PLC i ka loaʻa ʻana o ka ʻikepili ma o ka laina RTS a hiki i ke kaawale ma waena o nā pōʻai PLC ʻelua.

Loaʻa nā hana PLC ma o COM1 wale nō i nā āpau ma waena o nā pōʻai polokalamu PLC. Hoʻopuka pū ʻia nā huaʻōlelo ma o COM1 wale nō i nā āpau ma waena o ʻelua pōʻaiapili papahana. ʻO ka haʻahaʻa o ka hoʻohana ʻana i ka PLC a ʻoi aku ka lōʻihi o nā āpau ma waena o nā pōʻai papahana, ʻoi aku ka kiʻekiʻe o ka helu kamaʻilio me COM1.

07KT93

ABB 07KT93 GJR5251300R0101 Manaʻo Manaʻo Manaʻo

He aha nā mea hoʻohana o ka module controller ABB 07KT93 GJR5251300R0101?
ʻO ka ABB 07KT93 Advant controller module he ʻāpana o ka Advant Controller 400 (AC 400) series, ʻo ia ka mana maoli a me ka ʻōnaehana automation no nā kaʻina hana. Hoʻohana pinepine ia i ka nānā ʻana i nā noi i ka hana ʻana a me ka automation uila

No ke aha i hoʻomaka ʻole ai ka module 07KT93?
Pilikia pili mana: E nānā inā pili maʻamau ka lako mana 24V DC a inā ua poino a hemo paha ke kaula mana. Ua hewa paha ka module pono'ī. E ho'āʻo e hoʻololi i kekahi module hou no ka hoʻāʻo ʻana.


  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou