EPRO PR6423/10R-030 8mm Eddy Current Sensor
General info
Manufacture | EPRO |
Item No | PR6423/10R-030 |
Article number | PR6423/10R-030 |
Series | PR6423 |
Origin | Germany (DE) |
Dimension | 85*11*120(mm) |
Weight | 0.8 kg |
Customs Tariff Number | 85389091 |
Type | Eddy Current Sensor |
Detailed data
EPRO PR6423/10R-030 8mm Eddy Current Sensor
Non-contact sensor designed for critical turbomachinery applications such as steam,gas and hydro turbines, compressors, gearboxes, pumps and fans to measure radial and axial shaft dynamic displacement; position, eccentricity and speed.
Performance:
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF) ISO: 8 V/mm (203.2 mV/mil) ± 5% @ temperature range 0 to 45°C (+32 to +113°F)
Deviation from best fit straight line (DSL) ± 0.025 mm (± 1 mil)@ temperature range 0 to 45°C (+32 to +113°F)
Measuring Target:
Minimum Shaft Diameter 25 mm (0.79”)
Target Material (Ferromagnetic Steel) 42CrMo4 (AISI/SAE 4140) Standard Other (On Request)
Environmental, General:
Protection Class IP66, IEC 60529
Operating Temperature Range Sensor incl. 1m Cable: -35 to +200°C (-31 to 392°F),Cable & Connector: -35 to +150°C (-31 to 302°F)
Material Sensor Tip (PEEK Polyether Ether Ketone), Case (Stainless Steel),Cable (PTFE Polytetrafluoroethylene),Connector (Brass, nickel-plated)
Weight (Sensor with 1m Cable) Approx. 100 grams (3.53 oz)
Compliance and Certifications:
CE 2014/30/EU (EN 61326-1),2014/34/EU,2011/65/EU
ATEX EN 60079-0,EN 60079-11
IEC-Ex IEC 60079-0,IEC 60079-11,IEC 60079-26
CSA CAN/CSA-C22.2 NO. 0-M91,CAN/CSA-C22.2 NO. 157-92,CAN/CSA-C22.2 NO. 213-M1987,CAN/CSA-E60079-15-02 (R2006),CAN/CSA-C22.2 NO. 25-1966,CAN/CSA-C22.2 NO. 61010-1-04,ANSI/UL Standard 913-2004,ANSI/UL Standard 1604-1995,UL 60079-15 2002,UL 61010-1
Hazardous Area Approvals:
Intrinsic Safety (ia)
ATEX / IEC-Ex / CSA Area classification depends on converter,see converter documentation for details.Sensor temperature classification:
T6: Ta ≤ 64°C
T4: Ta ≤ 114°C
T3: Ta ≤ 160°C
Non-sparking (nA)
ATEX / IEC-Ex / CSA Area classification depends on converter,see converter documentation for details.Sensor temperature classification:
T6: Ta ≤ 64°C
T4: Ta ≤ 114°C
T3: Ta ≤ 160°C