ABB TK852V010 3BSC950342R1 Shielded FTP CAT 5e Cross-Over
General info
Manufacture | ABB |
Item No | TK852V010 |
Article number | 3BSC950342R1 |
Series | 800xA Control Systems |
Origin | Sweden |
Dimension | 73*233*212(mm) |
Weight | 0.5kg |
Customs Tariff Number | 85389091 |
Type |
Prefabricated Cable
|
Detailed data
ABB TK852V010 3BSC950342R1 Shielded FTP CAT 5e Cross-Over
ABB TK852V010 3BSC950342R1 Shielded FTP CAT 5e Crossover Cable is a special industrial Ethernet cable designed for ABB automation systems. It is used in systems that require fast and reliable communication to connect various devices such as PLCs, drives, communication interfaces and other networked automation equipment. TK852V010 ensures high-quality signal transmission, especially in industrial environments where electromagnetic interference (EMI) may interfere with communication.
The shielded FTP design combines the advantages of twisted pair cabling for reducing crosstalk and signal interference between wires and shielding around the wire pairs to protect against external electromagnetic interference (EMI) or radio frequency interference (RFI).
Shielding enhances signal integrity.
CAT 5e is an enhancement of the traditional CAT 5 cable, supporting higher data rates up to 1000 Mbps and transmission distances up to 100 meters. It supports Gigabit Ethernet and is suitable for modern industrial Ethernet communication protocols.
Crossover cable is used to directly connect two similar devices. In the case of ABB Automation, it can be used for direct communication between ABB devices, allowing faster point-to-point communication in networked systems.
Frequently asked questions about the product are as follows:
-What is the purpose of the ABB TK852V010 3BSC950342R1 Shielded FTP CAT 5e Crossover Cable?
The ABB TK852V010 is an Ethernet cable designed for industrial applications. It is used to connect ABB devices in a shielded high-speed Ethernet network. The crossover design enables direct device-to-device communication.
-What does the term "crossover" mean in the context of the TK852V010 cable?
In Ethernet networks, crossover cables are used to connect two devices of the same type directly without the need for a hub, switch, or router. The wires in a crossover cable are routed in such a way that the transmit and receive pairs are swapped, allowing the two devices to communicate directly.
-What is the significance of the cable being shielded and FTP?
The shielded FTP design provides additional protection against electromagnetic interference (EMI), which is especially important in industrial environments with high levels of electrical noise. The foil shield helps maintain signal integrity and prevents data corruption caused by external noise or electrical interference. In environments with high levels of interference, the FTP design is superior to unshielded twisted pair (UTP) cables.